Electrical Resistance Probes are advanced online corrosion monitoring devices that enable real-time measurement of metal loss within pipelines and process systems. Based on the principle that corrosion thinning increases electrical resistance, these probes provide continuous, accurate data without requiring system shutdown or physical retrieval. Suitable for a wide range of industrial environments, they serve as an essential tool for predictive maintenance and integrity management.

| نام | EMT-CP High Pressure Elecrical Probe For Pipeline Testing | |
| مادی | Stainless Steel 316、L DUPLEX SS | |
| دمای عملیاتی | -20~200℃ | |
| ویژگی | اولا ، کار ساده | |
| ثانیا ، با دقت زیاد عمر طولانی | ||
| At last, high Efficiency Low cost | ||
| پرداخت | TT/LC | |
| مزایا | Firstly, they are light weight and flexible. | |
| و سپس راندمان تزریق خوب. | ||
| در آخر ، ردیابی دقیق موقعیت مکانی. |
مزایا
-
Broad Applicability: Electrical Probes can be used in various media, including gas, liquid, solid, and flowing particles, demonstrating high versatility.
-
Ease of Operation and Real-Time Monitoring: The probes enable direct monitoring without the need for sampling. Their operation is simple and efficient, allowing for real-time data acquisition and analysis.
-
Rapid Response Time: They offer a significantly faster response compared to traditional methods like the weight loss technique, making them more suitable for dynamic conditions.

پارامترها
| Technical specifications | |
| Output signal | Wired form: RS-485 signal; |
| Wireless form: LORA, 4G/5G wireless network signal | |
| Power supply voltage | 9-36VDC |
| Rated operating voltage | 9VDC |
| Meter power consumption | 5.4W (Wired) |
| Linear | 0.0015% non-linear |
| Resolution | 17 bit |
| شرح | 25.6 mV |
| Accuracy | ±0.2% F.S (full scale) |
| Corrosion rate range | When the electrode area is 1cm², the measurement range is 4X10-4~10mm/a |
| Working and storage conditions | |
| دمای عملیاتی | -40~70℃ |
| Storage temperature | -40~85℃ |
| Structural parameter | |
| Protection level | IP66 |
| Shell material | Cast aluminum or PVC, aviation aluminum, stainless steel can be customized |
| Process interface | 7/8-20UNEF (Insert probe) |
| Electrical connection | M20*1.5mm |
| Access cable Model | RVVP 2*1.5mm² (حداقل استاندارد برنامه) |
| نصب | The probe is installed directly on the pipeline, and the transmitter can be installed in one piece or separately through the cable |
| وزن | 500 گرم |
| Split type accessory | Interface: MS-14-6S double female head |
| Split connection cable | Cable length: 1-3 meters can be customized |